IKEA UPPÅTVIND 604.982.28 Air Purifier instructions manual

The IKEA UPPÅTVIND 604.982.28 is a compact, efficient air purifier designed for small to medium rooms. It features a 3-stage filtration system (pre-filter, activated carbon filter, and HEPA filter), 3 fan speeds, a filter replacement indicator, touch controls, energy-saving mode, and a quiet night mode. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Placement 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Operating Modes 7. Maintenance & Filter Replacement 8. Energy Saving Tips 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit with integrated filters, Control Panel, Air Inlet Grille, Air Outlet, Power Cord, and Filter Replacement Indicator.

FeatureDescription
3-Stage FiltrationPre-filter, Activated Carbon filter, and True HEPA filter
Fan Speeds3 levels (Low, Medium, High) plus Auto mode
Filter IndicatorLED light alerts when filter needs replacement
Touch ControlsPower, Fan Speed, Timer, Night Mode
Night ModeQuiet operation with dimmed lights
Timer2, 4, 8 hour settings
Auto ModeAdjusts fan speed based on air quality
Power CordDetachable for easy storage
Air Quality IndicatorColor-coded LED (Blue=Good, Amber=Fair, Red=Poor)
Child LockPrevents accidental setting changes

Installation & Placement

Unpack and inspect contents. Choose optimal location for air flow.

  1. Remove all packaging materials from the unit and filters.
  2. Place on a flat, stable surface at least 15 cm from walls and furniture.
  3. Ensure air inlet and outlet are not obstructed by curtains or objects.
  4. Plug the power cord into a standard 120V AC outlet.

WARNING! Do not place in humid areas like bathrooms. Keep away from heat sources and direct sunlight.

First-Time Setup

Power on the purifier; follow initial setup steps.

  1. Insert filters: Open rear cover, install pre-filter, carbon filter, and HEPA filter in correct order.
  2. Reset filter indicator: Press and hold Filter button for 5 seconds after installing new filters.
  3. Select language for indicators (if applicable).
  4. Choose initial settings: Recommended to start in Auto mode.

CAUTION! Handle filters carefully; do not touch the HEPA filter media with bare hands.

Specifications

Controls and Settings

Access all functions via the touch control panel on top of the unit.

Control Panel: Power button, Fan Speed (Low/Med/High/Auto), Timer (2/4/8 hrs), Night Mode, Filter Reset, Child Lock.

Operation: Press Power to turn on/off. Cycle through fan speeds with Speed button. Set timer for automatic shut-off. Activate Night Mode for quiet operation and dimmed lights. Enable Child Lock by pressing and holding Power and Speed buttons for 3 seconds.

Operating Modes

Auto Mode: Automatically adjusts fan speed based on built-in air quality sensor. Manual Mode: Choose from Low, Medium, or High fan speeds. Night Mode: Reduces noise and dims lights for undisturbed sleep. Timer: Set to run for 2, 4, or 8 hours before automatically turning off.

  1. For general use: Auto mode recommended.
  2. For allergies: Run on High speed for 1 hour, then switch to Auto.
  3. For sleeping: Use Night mode or Low speed.
  4. For odors: Use High speed with new carbon filter.

Tip: Keep doors and windows closed for optimal purification performance.

Maintenance & Filter Replacement

Regular maintenance ensures optimal performance.

  1. Pre-filter: Vacuum monthly; replace every 3 months.
  2. Carbon filter: Replace every 6 months.
  3. HEPA filter: Replace every 12 months (or when indicator light turns on).
  4. To replace: Turn off and unplug unit. Open rear cover. Remove old filters and insert new ones in correct order. Reset filter indicator.

WARNING! Always unplug before maintenance. Use only genuine IKEA replacement filters.

Energy Saving Tips

Use Auto mode for efficient operation. Enable Timer to avoid unnecessary running. Use Night mode during sleep hours. Clean pre-filter regularly to maintain airflow efficiency. Place unit in central location for better air circulation.

Care & Cleaning

Unplug before cleaning. Wipe exterior with soft, dry cloth. Clean air inlet and outlet grilles with soft brush attachment of vacuum. Do not use water, liquids, or chemical cleaners on the unit.

CAUTION! Never immerse unit in water. Do not use abrasive cleaners that may damage surfaces.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. CE marked for European compliance. Energy Star certified for energy efficiency. For support, visit www.ikea.com or contact IKEA customer service at 1-888-888-4532. Dispose of filters according to local regulations; electronic waste should not be disposed of with household trash.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not turning onPower issueCheck power connection; ensure outlet is working; try different outlet.
Reduced airflowClogged filtersClean or replace filters as needed; check for obstructions.
Filter light onFilter needs replacementReplace appropriate filter; reset filter indicator.
Unusual noiseObstruction or loose partCheck for objects near fan; ensure filters are properly installed.
Bad odorDirty filters or new filter smellReplace carbon filter; run on High for 2 hours to dissipate new filter smell.
Auto mode not workingSensor issueClean sensor area; reset unit by unplugging for 1 minute.

Reset: Unplug for 1 minute to reset electronic controls.

Service: 1-888-888-4532; www.ikea.com

IKEA UPPÅTVIND 604.982.28 Air Purifier instructions manual © - All Rights Reserved 2025