The IKEA AGARALG 704.902.03 is a lighting fixture designed for indoor use. This manual provides essential information for the safe installation, operation, and maintenance of the product. It includes details on assembly, electrical connection, bulb replacement, safety warnings, and troubleshooting. Please read all instructions carefully before beginning installation.
Safety Information
To prevent fire, electric shock, or personal injury, follow these safety precautions.
| Warning | Instruction |
| Electrical Hazard | Always turn off power at the circuit breaker before installation or maintenance. |
| Heat Hazard | Allow bulb to cool before touching. Use only recommended bulb type and wattage. |
| Mounting Surface | Ensure the ceiling or wall can support the weight of the fixture. |
| Water & Moisture | This is an indoor fixture. Do not install in bathrooms, outdoors, or damp locations unless rated for such use. |
| Children | Keep packaging materials away from children to avoid suffocation risk. |
Package Contents
Unpack all parts and verify contents against this list before discarding packaging.
- Main lighting fixture body (AGARALG 704.902.03)
- Mounting bracket
- Wire connectors (2-3 pcs)
- Mounting screws and wall plugs
- Glass or plastic shade/diffuser (if applicable)
- This instruction manual
IMPORTANT! If any part is missing or damaged, do not proceed with installation. Contact IKEA customer service.
Product Overview
Key components of the AGARALG lighting fixture.
- Fixture Body: Houses electrical components and bulb socket.
- Mounting Bracket: Attaches to the ceiling/wall junction box.
- Shade/Diffuser: Covers the bulb for light distribution and safety.
- Terminal Block/Wires: For connecting household electrical wires (typically Live/Brown, Neutral/Blue, Ground/Yellow-Green).
- Bulb Socket: E26/E27 or as specified for your region.
Assembly Instructions
Assemble the fixture on a clean, soft surface before mounting.
- Attach the mounting bracket to the fixture base using provided screws (if not pre-attached).
- If included, carefully attach any arms, stems, or decorative elements as shown in the diagram.
- Do not fully tighten all screws until the final alignment is complete.
- Keep the glass/plastic shade aside until after electrical connection is complete.
CAUTION! Handle glass or plastic parts with care to avoid breakage.
Electrical Installation
WARNING: TURN POWER OFF AT THE CIRCUIT BREAKER.
- Remove the existing fixture (if any).
- Identify wires in your ceiling/wall junction box: Live (L), Neutral (N), and Ground (Earth).
- Connect fixture wires to house wires: Live to Live (Brown to Brown/Black), Neutral to Neutral (Blue to Blue/White), Ground to Ground (Green/Yellow to Green/Yellow or metal junction box).
- Use provided wire connectors. Twist wires together securely and screw on connectors.
- Neatly tuck all connected wires into the junction box.
Mounting to Ceiling/Wall
Secure the fixture to the junction box.
- Align the mounting bracket (attached to fixture) with the holes on the junction box.
- Use the provided screws to secure the bracket firmly to the junction box.
- Ensure the fixture is stable and does not wobble.
- If applicable, attach the fixture canopy or cover plate to conceal the junction box and wires.
Tip: A helper can hold the fixture in place while you secure it.
Bulb Replacement
Use only the recommended bulb type to avoid damage and overheating.
- Ensure the fixture is cool and power is turned off.
- Gently remove the shade/diffuser (usually twists counter-clockwise or is held by clips).
- Unscrew the old bulb and dispose of it properly.
- Screw in the new bulb. Do not exceed the maximum wattage indicated on the fixture label (e.g., Max 60W). LED or CFL bulbs are recommended for energy efficiency.
- Reattach the shade/diffuser securely.
Operation
Operate the light using your existing wall switch.
- Turn power back on at the circuit breaker.
- Use the wall switch to turn the light ON and OFF.
- If the fixture includes a pull chain or dimmer, follow its specific operation instructions.
Note: Some energy-saving bulbs (CFL/LED) may have a short delay when turning on or may not be compatible with dimmers unless specified.
Care & Maintenance
Unplug/turn off power before any cleaning.
Use a dry, soft cloth to dust the fixture and shade. For plastic shades, a damp cloth with mild soap can be used. Dry thoroughly. Do not use abrasive cleaners, chemicals, or solvents.
CAUTION! Never immerse the fixture in water or other liquids.
Specifications & Compliance
- Model: AGARALG 704.902.03
- Input Voltage: 120V AC, 60Hz (or 230V AC, 50Hz depending on region).
- Max Wattage: [Check fixture label, e.g., 60W Max]
- Bulb Base: E26/E27 or as specified.
- Dimmable: Check fixture label. If not stated, assume non-dimmable.
- Safety Standards: Complies with relevant national and international electrical safety standards.
- Warranty: Refer to the IKEA warranty card included with your purchase.
Troubleshooting
| Symptom | Possible Cause | Corrective Action |
| Light does not turn on | Power off / Bulb burnt out / Loose connection | Check circuit breaker. Replace bulb. Ensure all wire connections are tight. |
| Light flickers | Loose bulb / Incompatible dimmer / Faulty bulb | Tighten bulb. Use a non-dimmable bulb or compatible dimmer. Try a different bulb. |
| Fixture is hot to touch | Bulb wattage too high | Immediately turn off and replace with a bulb of the correct, lower wattage. |
| Buzzing sound | Incompatible dimmer / Faulty ballast (if fluorescent) | Use a compatible LED/CFL dimmer or non-dimmable bulb. For fluorescent, replace starter or ballast. |
| Shade/diffuser loose | Not properly secured | Turn off power. Ensure shade is correctly aligned and twisted or clipped into place. |
For Support: Visit www.ikea.com or contact your local IKEA store.